  amaha windows 貼片機常見報警及解決方法1、PCB傳輸故障:①E0070:PCB TRANSFER ERROR Unexpected PCB is on the Conveyor PCB傳輸故障,額外的PCB在運輸軌上意義:在運輸軌上的PCB,數量超過額定的數量。②E0071:The PCB detected before transfer is not detected after transfer. Maybe there is the PCB on the edge of the moving conveyor . Set the PCB to its normal Position Manually. 傳輸前檢測的PCB在傳輸后檢測不到,可能在移動運輸軌的邊緣有PCB,用手將PCB放置在其正常的位置。意義:載入開始檢測的PCB在載入后不能確認,卸出前確認的PCB在出口處檢測不到,或載入卸出前不能確認的PCB 在載入卸出后被檢測到。③E0072:Machine in Unable to start running because the conveyor width is not ready . The conveyor width will be changed first . Misaligment of PUSH-UP PINS or PCB on conveyor may danage machine . Assure Safety and push the [ENTER] key. 意義:因未準備運輸軌寬度機器不能開始運行,運輸軌寬度將先被改變,在運輸軌上的PCB或上推頂針的失調可能損壞機器,確保**并按[ENTER]鍵。④E0073:PCB is detected on the edge of the moving conveyor. Set the PCB to its normal Position mannally. 在移動運輸軌邊上檢測到PCB,將PCB手動放置在正常位置。意義:在移動運輸軌的的連接部分,危險警告傳感器檢測到一塊PCB。⑤E0074:PCB FIXING ERROR PCB trans-Unit, Locate-Pin or push-up-Unit does not response to command. PCB固定故障 PCB傳輸部件,定位針或上推部件不響應指令。意義:在PCB傳輸部件上的定位針傳感器或上推部件,傳感器不能正確響應電磁閥的狀況。⑥E0078: When the PCB was transfered to fixed conveyor of PCB exit Side ,error happened for time over Maybe the PCB stoppered between fix conveyor and moving enveyor or the PCB stopped is fixed Conveyor of PCB exit side . Set the PCB to its normal position mannally. 當PCB 傳送到PCB出口處邊的固定運輸軌時,發生超時故障,PCB 可能停在固定運輸軌和移動軌之間,或PCB停在PCB出口邊的固定運輸軌中,用手將PCB放在正常位置。意義:當從運輸軌上卸出PCB時,PCB不能到達出口傳感器。⑦E0079: The PCB was not able to exit from fixed conveyor of PCB exit side . Maybe the PCB stopped on edge of fixed conveyor of PCB exit side. Set the PCB to its mormal position mannally. PCB不能從出口邊的固定運輸軌出來,PCB可能停在PCB出口邊固定運輸軌邊上,手動將PCB放在正常位置。意義:PCB不能載出到下一工序。⑧E0080:Moving conveyor can’t net move, because there is the PCB on the edge of the moving conveyor . Set the PCB to its normal position mannally. 移動運輸軌不能移動,因為在移動運輸軌邊緣有PCB ,手動將PCB放于正確位置。意義:工作臺A和B之間有一塊PCB ,阻礙工作臺移動。⑨E0081:Fixed conveyor of PCB entrance side stopper for time over. Check whether the PCB stops in fixed conveyor of PCB extrance side . PCB入口邊的固定運輸軌因超時停止,檢查是否有PCB停止在入口邊的固定運輸軌中。意義:一塊PCB載入無問題,但不能運到準備位置的傳感器處。⑩E0082: PCBS are found both on extrance and extrance stopper, check whether more than 1 PCBS are conveyed to the working position. 在入口處和入口擋板上發現PCBS,檢查是否多過一塊PCBS運送到工作位置。2、丟料故障E0075:DUMP STATION FULL Dump station is filled with components. Please remove the components manually from the dump Station then start again. 丟料站滿 丟料站上元件滿溢,請用手從丟料站上移走元件,然后再開始。3、元件計數停止故障:E0076:COMPONENT COUNT STOP Component counter reached to specified number, Fill the component and run again . 元件計數停止元件計數器達到規定的數目,裝上元件并重新運行。Componeht data 151 元件數據Feeder Set position 21 供料器安裝位置意義:測試運行期間,測試的規定數目運行后發生故障。4、托盤供料器故障① E0300: Tray unit error: The component is not placed correctly on the traverser station. If the component is on the station, Please remove it . 托盤單元故障:元件未正確放置在送料橫梁的站上,如果元件留在站上,移走它。Mount data 765 貼裝數據Component data 153 元件數據Station 2 站Next tray position is for the next pick sequerice (x=6, y=3) 下一托盤位置是用于下一拾取工序的(x=6, y=3?意義:托盤供料器不能將元件放置在橫梁站上,如果額外的元件放在規定的橫梁上,移開它。②E0301:Tray unit error: Returned component is not placed correctly on the traverser station. If the component is on the station. Please remove it 托盤部件故障,退回的元件未正確放置在橫梁站上,如果在橫梁站上有元件,請移開它。意義:從主機退回的元件不能正確放置在橫梁站上。③E0302:Tray unit error: Returned component is not placed correctly on the traverser station . If the component is on the station,please remove it . 托盤部件故障:不能從托盤上拾取元件,托盤部件不能從下面的托盤位置拾取元件。Mount data 765 貼裝數據 Component data 153 元件數據 Station 2 站Next tray position is for the next pick sequence (x=6, y=3) 下一托盤位置是用于下一拾取工序的(x=6, y=3)。 意義:不能從托盤上拾取元件。

你可能感興趣:
無覓相關文章插件,快速提升流量